NYM-J 5 x 1.5 mm² Cable 25 m Sheathed Cable, Wet Room Cable in Accordance with DIN VDE 0250-204, Electric Cable, 5-Core Copper Power Cable for Electrical Installation in Light Grey, Length in One Piece, German Brand Manufacturers

NYM-J 5 x 1.5 mm² Cable 25 m Sheathed Cable, Wet Room Cable in Accordance with DIN VDE 0250-204, Electric Cable, 5-Core Copper Power Cable for Electrical Installation in Light Grey, Length in One Piece, German Brand Manufacturers

Wet room cable NYM-J 5 x 1.5 mm².

The power cable is suitable for laying over, on, in and under plaster in dry, damp and wet rooms, as well as in masonry and concrete (not for vibrated, vibrated or compressed concrete).
The light grey PVC jacket of the cable is easy to work with, peel and shape. For this reason, the power line can be easily laid even in tight places.
NYM cables are not UV light resistant and therefore need to be protected from direct sunlight outdoors. They are not approved for the soil and the outside kingdom.
The core of the wet room cable is made of copper and thus ensures ideal conductivity.

  • Cable type: NYM-J 5 x 1.5 mm² wet room cable, 5-core with a cross section of diameter 1.5 mm².
  • Lead colours: Blue, Brown, Grey, Black, Green/Yellow
  • Coating: PVC – odourless.
  • Installation temperature: min. 5 °C to 70 °C.
  • Operating temperature: -40 °C to 70 °C.
  • Voltage class: 300/500V.
  • Operating voltage DC: max. 825 V DC.
  • Operating voltage AC: max. 550 V AC voltage.
  • Fire behaviour: fire transmission according to DIN EN 603332-1-2.
  • Standards: ISO DIN VDE 0250-204 | IEC 228 & HD 383.
  • Manufacturer: various German brand manufacturers (delivery according to stock availability).
  • Box contents: cable length according to length selection – cable as ring with length in one piece.



Wet room cable type: NYM-J 5 x 1.5 mm², 5-core power cable (blue, brown, grey, black, green/yellow) with outer diameter 10 mm +/-1 mm
Electric cable standard: voltage class 300/500 V, ISO DIN VDE 0250-204, IEC 228 and HD 383 EU wide approved, fire behaviour: fire transmission according to DIN EN 60332-1-2
Areas of use: electrical installation cables for laying over, on, in and under plaster in dry, damp and wet rooms, as well as in masonry and concrete.
Not suitable for: embedding in vibrated, vibrated or mashed concrete and soil. Suitable for outdoor use when protected from direct sunlight but not approved.
Box contents: 25 m cable as a ring in one piece. From various German manufacturers according to stock availability